The API Chamber is intended for the safe handling and weighing of APIs. Provides maximum safety for both the user and the sample, like no other device in the market.

Thanks to its innovative design, it prevents the release of API into the laboratory atmosphere. Likewise, it impedes dispersion, loss or degradation of the sample, so that its properties remain unaltered.

Sello EOB Certified Level 5
The API Chamber of Burdinola

Maximum Safety
for the user and the specimen

Burdinola API Chamber robustness and safety

ROBUSTNESS AND SAFETY

Steel structure. Safety features against explosions.

Burdinola API Chamber containment

CONTAINMENT

Vertical multilaminar flow.

Burdinola API Chamber ergonomic

ERGONOMICS

Large interior space. Sash opening up to 450 mm.

Burdinola API Chamber energy efficient double filtering system

ENERGY EFFICIENT DOUBLE FILTERING SYSTEM

Incorporates Burdinola’s patented Caresafe Curtain system.

All the advantages
of the new API Chamber

1. Maximum safety

Maximum safety for the user and the working environment in all API applications, both in handling during tests and using analytical equipments.

  • Containment, robustness and efficiency. Efficient containment for all sample types and sizes, even in adverse external conditions.
  • The use of a vertical laminar flow at low air speeds, does not generate turbulences, thus eliminating the risk of release of any API outside.
  • Air extracted to the exterior, impeding recirculation of materials in the room.
  • Double air filtering system.
  • Bag-in/Bag-out filter replacing system in order to avoid any risk during the process.

2. Sample properties remain unaltered

Sample properties remain unaltered since dispersion and agglomeration of the sample are avoided.

  • Zero turbulence thanks to the vertical laminar flow system.

3. Highly energy-efficient

Very low speed operation: < 0.2 m/s compared to the 0.35 m/s - 0.45 m/s required in other systems. Air speed adjustable from 0.2 m/s to 0.45 m/s.

4. Containment robustness testing

Containment robustness testing, specific to API applications.

The requirements of standard EN 14175-3 are exceeded.

  • Static and dynamic containment tests according to EN 14175-3.
  • Static containment tests with Dummy according to EN 14175-3.

Tests adapted to API technology.

  • Containment robustness tests.
  • Trials of adapted procedure with API particles.
  • Smepac cointanment system test: OEB level 5 certified.

5. Multifunction

Specific chamber to work with APIs that also includes the weighing table function that incorporates a six-digit weighing capability.

6. Ergonomic

  • Sash opening up to 450 mm and operational opening of 200 mm.
  • The sash can be adjusted between 25 mm and 450 mm.
  • Contactless motorized sash.
  • Useful interior space depending on the model: 1200/1500 x 560 x 1045 mm.

7. Robustness of chamber against possible explosions

Robustness of chamber against possible explosions 15 cm thick steel structure (sides) vs 2 cm in traditional cabinets. Explosion-resistant chamber.

OEL - Operator Exposure Limit describes the average concentration of the active substance in ug/m3 within the breathing area of operating personnel over an eight-hour period.

OEB - Operator Exposure Band characterizes the degree of toxicity of the substance on a containment scale of 1 to 6.

Burdinola API Chamber smepac cointanment system test: OEB level 5 certified.